General Services Administration (GSA) seeks to lease the following space:
State:
FL
City:
St. Petersburg
Delineated Area:
North - 9th Ave N
West - Dr. Martin Luther King Jr St. N
East - Bayshore Drive NE and Beach Dr SE /
South - 18th Ave S
Minimum Sq. Ft. (ABOA):
38,302
Maximum Sq. Ft. (ABOA):
40,217
Space Type:
Office
Parking Spaces (Total):
19 (refer to the “Additional Requirements”)
Parking Spaces (Surface):
19
Parking Spaces (Structured):
0
Parking Spaces (Reserved):
0
Full Term:
120
Firm Term:
120
Option Term:
2 five-year options
Additional Requirements:
If offering is a multi-floor building, the following functions (as delineated in Fisheries Space Program) must be located on the ground floor: Office of Law Enforcement (OLE), Security Guard Station, Mail Room, SERO/Permits, High Density Mobile Storage, and Office of General Counsel (OGC). High Density storage location is due to potential floor load safety requirements. Total SF is approximately 7,700 ABOA SF. The balance of the remaining space must be contiguous.
Space shall be located in a modern quality building of sound and substantial construction with a facade of stone, marble, brick, stainless steel, aluminum or other permanent materials in good condition and acceptable to the GSA Lease Contracting Officer. If not a new building, the space offered shall be in a building that has undergone, or will be complete by occupancy, modernization or adaptive reuse for the space with modern conveniences.
Space should allow for an efficient layout and office workflow. Space must provide maximum flexibility for systems furniture placement with few or no columns or other building or architectural obstructions. Space should have few curves or major offsets and must have large open areas to allow maximum design flexibility. Architectural features should not cause an inefficient use of space.
ABOA SF does not include areas such as stairs, elevators, mechanical and utility rooms, ducts, shafts, vestibules, public corridors, and public toilets required by local code.
This requirement will house a federal law enforcement office where employees will carry weapons, weapons will be stored on-site, and individuals may be temporarily detained and/or questioned.
If the proposed site is a multi-tenant building/property, the other tenants/uses shall not be any of the following types (items 1-12). Risk/vulnerability assessment of the property will be on a case by case basis.
1. Residential units
2. Retail units that cater to heavy public use or heavy foot/vehicle traffic
3. Probation, Pre-Trial, and Federal Public Defender
4. Mental Health Facilities (Psychiatrist or Psychologist)
5. Drug Treatment Facilities (Drug Counseling or Drug Treatment Clinics)
6. Blood or Plasma Donation Centers
7. Bail Bond Businesses
8. Criminal Rehabilitation or Reintegration Services such as Halfway Homes
9. Law Firms Specializing in Criminal Defense or Immigration cases
10. Social Service Organizations, to include organizations that provide assistance to crime victims and immigrants
11. Temporary Labor Services, such as a Day Labor Providers.
12. Drug/medical marijuana dispensary (nor shall this usage be located within 1000' of the property).
Secure area for Dive Tank Storage/equipment.
Requires 24/7 Power (emergency generator system) and AC support for server room(s) and network work(s), climate controls must be able to maintain temperatures 64-75 degrees F with relative humidity between 30%-55%.
Full-service Generator Back-up either existing or ability to be added.
A fully serviced lease is required.
Require access to a loading dock.
Parking Requirements:
In addition to the 19 secure fenced with operable gate federal vehicle parking spaces for Government vehicles; located adjacent to building (no further than 500 feet), located off parking area.
· there will need to be 5 designated visitor parking spaces
· there will need to be sufficient parking up to 190 employees
· parking for 2 boats with trailers that are up to 35’ in length.
Other requirements:
· Secure with Gate Wareyard = 1,500 RSF to include space for 144 foot field equipment storage unit and mobile 12 foot OLE storage unit trailer.
· Roof access required for 7 Antenna/Satellite devices. Roof will need to be able to accommodate small antenna mounts and conduit penetrations into the building. Regular access to these devices is required.
Offered space must meet Government requirements for fire safety, accessibility, seismic, and sustainability standards per the terms of the Lease. A fully serviced lease is required. Offered space shall not be in the 1-percent-annual chance floodplain (formerly referred to as 100-year floodplain).
Entities are advised to familiarize themselves with the telecommunications prohibitions outlined under Section 889 of the FY19 National Defense Authorization Act (NDAA), as implemented by the Federal Acquisition Regulation (FAR). ). For more information, visit: https://acquisition.gov/FAR-Case-2019-009/889_Part_B.
************************************************************************************************
Expressions of Interest Due:
(04/04/2024)
Market Survey (Estimated):
TBD
Occupancy (Estimated):
6/1/2026
Send Expressions of Interest to:
Name/Title:
Melissa Hein
Office :
212-326-1064
Email Address:
Melissa.Hein@gsa.gov
Government Contact Information
Lease Contracting Officer
Keitra.Harris@gsa.gov
Broker
Melissa.Hein@gsa.gov