BAEY 240015 - Replace Fire Pump Controllers

Key Details
Buyer
DEPT OF DEFENSE
Notice Type
Sources Sought
NAICS
541330
PSC
J042
Due Date (Hidden)
Next 3 months
Posted Date (Hidden)
Key Dates
Posted Date
December 10, 2024
Due Date
January 20, 2025
Place of Performance
CA
Sam.gov Link
Link
Description

This contract opportunity serves as a presolictation for the following requirement:

BAEY 240015 Upgrade Fire Pump Controllers at B11600 located at Beale Air Force Base (AFB), California. The services to be performed shall include demolition of the existing fire alarm system and fire pump controllers, design and construction of a new fire alarm system and fire pump controllers. Project also includes installation of a ductless split system air conditioner with programmable thermostat. See site map for location and layout.


Building 11600 pump house provides dedicated fire water for aircraft hangars 1-6. The site arrangement includes two water storage tanks and an associated water pumping facility that houses three electric fire pumps and two electric jockey pumps with associated controllers. The pump house facility was constructed in 2004. Subsequent projects have replaced selected equipment within the pumphouse except for the fire pump controllers. They are old and out of compliance with current standards and need replacement. The current fire alarm system does not provide adequate monitoring of the fire pump system which has resulted in reoccurring damage to fire equipment. The fire alarm system is out of compliance with current cyber security regulations and the space where the FACP is located is not properly temperature controlled. Improper reporting by the fire alarm system and old fire pump controllers pose a serious risk to the operability and maintainability of the system.
The Contractor shall furnish all design, labor, supervision, transportation, materials, testing, analysis, reports, permits, hauling, tools, equipment, disposal, and professional services to accomplish all the work involved to construct the project described in section 1.2. The completed project shall result in a fully functional and code compliant fire alarm system and fully operable/functional electric fire pump controllers meeting all government and industry standards.

This Notice will serve to satisfy synopsis requirements outlined in FAR 5.204. 

If there are any NAICS or PSC code that do not match the presolicitation posting and your company is able to fullfill this requirement please provide the approrpiate information in the Sources Sought Questionnare. 

Should there be any questions about the the Statement of Work or the accompanying documents, please notify the CA/CO. 